367 / Ti6AL7Nb
367 / Ti6AL7Nb. Implant alloy with excellent biocompatibility and high strength.
Request A Quote?
Product Details
Implant alloy with excellent biocompatibility and high strength.
Main fields of application of Ti6AL7Nb (Ti 6/7)
Endoprotheses: hip, knee, shoulder, hip-balls osteosyntheses; bone screws, bone plates, marrow-nails, spinal systems, oral implants.
Chemical composition of Ti6AL7Nb (Ti 6/7)
Al | 5.5 - 6.5 | C | ≤ 0.08 |
Nb | 6.5 - 7.5 | H | ≤ 0,009 |
Fe | ≤ 0.25 | Ti | bal |
O | ≤ 0.20 | N | ≤ 0,05 |
Mechanical properties of Ti6AL7Nb (Ti 6/7)
annealed | specification values (ASTM F1295) |
tensile strength Rm | ≥ 900 |
yield-strength Rp 0.2 | ≥ 800 |
elongation A | ≥ 10% |
Delivery program
dim. (Ø) mm kg/m tolerances stock | kg/m | tolerances | stock |
6,0 | 0,127 | h8 | ● |
0,8 | 0,227 | h8 | ● |
12 | 0.51 | h8 | ● |
13 | 0,59 | h8 | ● |
15 | 0,80 | h8 | ● |
25 | 2,21 | - 0.20 / + 0.20 | ● |
26 | 2,39 | - 0.20 / + 0.20 | ● |
35 | 4,34 | - 0.36 / + 0.36 | ● |
42 | 6,25 | - 0.40 / + 0.40 | ● |
Further bars and profiles in different executions available upon request.